Most settings are command-line options. The clock source, the MIDI clock input and the app’s look (Themes) are chosen in the app (File → Preferences…) and remembered. There is no settings file to edit.

How to pass options

  • Desktop app: create a Windows shortcut to seq-app.exe and add the options to its Target, for example "C:\Tools\Clip Sequencer\seq-app.exe" --osc-port 7001. Or run it from a terminal with the options.
  • Console: seq-app-cli.exe --midi-port loopMIDI.

Options

OptionDefaultWhat it does
--clock <source>the one saved in Preferences, else midiclock source for this run: midi (a MIDI clock) or resolume (Resolume’s tempo, Setting up the clock)
--midi-port <name>the one saved in PreferencesMIDI clock input for this run; part of the name is enough
--resolume-host <host>127.0.0.1where Resolume runs
--rest-port <port>8080Resolume’s webserver port (Preferences → Webserver)
--osc-port <port>7000Resolume’s OSC input port (Preferences → OSC)
--ui-port <port>8090port of the sequencer’s own UI (see below)
--strict-portexit with an error instead of trying other ports when the UI port is taken
--seq-layer <name>SEQthe layer that holds the placeholder clips
--seq-prefix <text>"§ "how placeholder clip names start
--data-dir <folder>%APPDATA%\clip-sequencerwhere sequences, settings, caches and logs are kept
--no-splashdesktop app: no splash screen, the window appears when ready
--headlessno window, UI in the browser (seq-app-cli.exe always runs like this)
--ffgl-dir <folder>the one chosen in the app, else Documents\Resolume Arena\Extra EffectsResolume’s plugin folder for the FFGL plugin

Commands of seq-app-cli.exe that print something and exit:

CommandWhat it does
--list-midi-portslists the MIDI inputs
--clock-debugshows the incoming clock (bar.beat.tick and BPM) on the port given with --midi-port
--validate <file>checks a .seq.json file (exit code 0 = valid)
--install-ffglinstalls or updates the FFGL plugin (Installing the FFGL plugin)
--versionprints the version, build number, commit and build date
--helplists all options

Desktop app and headless mode

seq-app.exe is the desktop app: one window, no console. seq-app-cli.exe runs the same sequencer without a window: it prints the startup steps and the log to the console, and you open the UI in a browser at the address it prints (normally http://127.0.0.1:8090). Ctrl+C, closing the console, or File → Quit server… in the browser stops it cleanly.

The UI port

The sequencer’s UI (and the FFGL plugin) talk to it on port 8090. If another program uses that port, the sequencer takes the next free one from 8091 to 8099, then any free port, and says so in the log. The window and the console always use the actual address. With --strict-port it exits instead.

If the port belongs to a sequencer that is already running, no second one starts: the desktop app offers to bring the running one to the front.

The FFGL plugin expects 127.0.0.1:8090; if the sequencer runs on another port, set the plugin’s Server parameter to match.

Network and security

The UI listens on 127.0.0.1 only: it can be opened on this computer, not from other devices. It has no password; any program on the computer can use it, like Resolume’s own webserver.

Recording

Preferences → Recording: Quantize (recorded clicks snap to sixteenths, eighths or beats) and Latency (ms; a click counts that much earlier, negative values later). Both apply at once, also to a recording that runs. Recording from Resolume.

Logging

Logs go to the Console tab and to daily files in logs\ in the data folder (kept for 7 days). For more detail, switch on Preferences → Log → Log debug messages: every OSC message sent to Resolume and each trigger’s confirmation are logged, with their times. It applies at once; turn it off for a show. (RUST_LOG=debug before starting also works, and adds the debug messages of the libraries the app uses.)